Back junction boxes
Blue Series junction boxes: versatile solutions for hollow walls.
- Wide range of sizes: from 107x107 mm to 300x500 mm.
- Cover options: with screws or metal claws.
- Secure mounting: using nylon ties or metal claws.
- Glow-wire test: 850 °C for references declaring this result; check the data sheet.
Flush connection box in hollow partition. 107 x 107 x 45 mm. Cover with screws. Fixing system with nylon ties.
Flush connection box in hollow partition. 100 x 100 mm. Metal claw cover. Nylon ties fixing system.
Flush connection box in hollow partition. 170 x 112 x 47 mm. Cover with screws. Fixing system with nylon ties.
Home automation box to embed in a hollow partition. 300 x 150 x 75 mm. With DIN35 profile
Flush connection box in hollow partition. 170 x 112 mm. Cover with metal claw. Nylon ties fixing system.
Flush connection box in hollow partition. 188 x 148 x 50 mm. Cover with screws. Fixing system with nylon ties.
Flush connection box in hollow partition. 250 x 250 mm. Cover with screws. Fixing system with nylon ties.
Flush connection box in hollow partition. 250 x 250 mm. Cover with screws. Fixing with metal claws.
Flush connection box in hollow partition. Ø 150 mm. Round cover with plastic claw. With central screw.
Blue junction boxes: connections and home automation in hollow walls
Solera Blue junction boxes accommodate connections, branches and compatible equipment in cavity walls. The range includes square, rectangular and circular formats, different depths and home automation versions. Selection must allow connection space, later access and the correct board anchoring.
References and differences
| Reference | Specified format or purpose |
|---|---|
| 5362GW | 107 × 107 × 45 mm |
| 5363GW | 170 × 112 × 47 mm |
| 5530GWD | Home automation box; 300 × 150 × 75 mm |
| 5503HGW | 300 × 500 × 85 mm |
| 5506HGW | 300 × 500 × 60 mm |
The table shows examples rather than one common size. The 5503HGW and 5506HGW share a stated 300 × 500 mm format but have depths of 85 and 60 mm. The 5530GWD is described as a home automation box. Before cutting, check whether a dimension is specified as internal, external or for recessing.
Selection and installation planning
Choose capacity according to connections, equipment mounting and access requirements. Check conduit entries and distinguish wall anchoring from cover closing. For example, 5362GW uses nylon ties for hollow-wall fixing; other references use claws. Confirm the cover system in the documentation for the exact model.
Consult Solera technical documentation to verify drawings, installation conditions and included parts. Also compare Wiring device boxes / ICT telecom enclosures. The Blue range for hollow walls page groups all branches.
Frequently asked questions — Junction boxes
How do 5503HGW and 5506HGW differ?
Both state a 300 × 500 mm format, but 5503HGW is 85 mm deep and 5506HGW is 60 mm deep. Check the available wall opening and cavity, along with cover and accessory details.
Is there a home automation version?
The 5530GWD is listed as a hollow-wall home automation box measuring 300 × 150 × 75 mm. Check equipment space, mounting and operating requirements before assembling the system.
Does a cover claw anchor the box to the wall?
These are separate functions. The data sheet distinguishes the cover closing system from the hollow-wall fixing system. A claw cover does not establish how the box body is anchored.