Network termination register.

Robust solutions for electrical and telecom installations.

  • Flush-mounted or surface-mounted: To suit all project needs.
  • With or without sockets: 2P+E, 16A 250V~ options for electrical connections.
  • Locking options available: Enhanced security with metal key systems.
  • Equipment housing by model: Check dimensions, mounting and requirements of active and passive components.

Network termination registers for homes

Solera network termination registers provide space to organise incoming telecommunications services and their distribution inside the home. Select the enclosure according to the mounting method, cables and equipment to be housed.

Empty enclosures, socket versions and combined assemblies

The range includes flush-mounted and surface-mounted models. For example, 5504/2 is an empty flush-mounted enclosure, while 5504/2B includes two 2P+E socket outlets rated at 16 A and 250 V AC. References with locks and specific hollow-wall versions are also available. Combined references such as 5250ICT and 5260ICT accommodate electrical distribution and telecommunications; their modular capacity describes the electrical distribution section.

Choosing a network termination register

  • Check usable dimensions and depth against the equipment and connection space required.
  • Review cable entries, fixings, available plates or rails and required cable bend radii.
  • For active equipment, assess power supply and ventilation. Socket outlets, plates and locks depend on the reference; network equipment is not necessarily supplied with the enclosure.

The reference configurator by housing type helps prepare an initial selection and lets you indicate whether a network termination register will be installed. Then check the result against the technical documentation and project requirements. See IT accessories to complete the assembly. For shared-building network connections, consult the secondary registers in the IT range.

Frequently asked questions

How do 5504/2 and 5504/2B differ?

The 5504/2 is an empty flush enclosure; 5504/2B includes two 2P+E sockets rated 16 A, 250 V AC. Both specify recess dimensions of 688 × 526 × 86 mm. Included sockets do not mean telecommunications equipment is supplied.

What do the modules of a combined electrical distribution and IT enclosure describe?

Module capacity refers to the electrical distribution space, not the number of network devices the enclosure can hold. Check the electrical layout separately from usable dimensions, mounting and ventilation of the telecommunications section for the selected reference.

Are all flush versions suitable for hollow walls?

Do not assume this. Specific references, such as 5260RTRHGW, are designed for hollow walls. Choose by the wall type and fixing system, checking recess dimensions and instructions. A version for another support is not equivalent simply because it has a similar size.