Fyx systems, terminals and Nylon ties
- Solera connection devices, terminals and insulation provide solutions for joining, distributing and terminating conductors, alongside heat-shrink tubing for insulation.
- CLE / REV / RE / TCD / CLC / CE / CTR / TBR.
- IP68 connectors / Splices and heat-shrink tubing / Distribution blocks.
IP68 flush connectors
Heat shrink tubing and connectors
Terminal Blocks
Terminals (dominoes)
Fast terminal blocks
Terminal block 1 way entry
DIN rail terminals
Wire connectors
Solera electrical connections: connectors, terminal blocks, terminals and insulation
Solera connection devices, terminals and insulation provide solutions for joining, distributing and terminating conductors, alongside heat-shrink tubing for insulation. The family includes quick connectors, in-line and strip terminal blocks, DIN terminals, cap connectors, IP68 connectors and distribution blocks. Each group has a different purpose: select for conductor type, section, mounting and use conditions.
Reference comparison
| Format / layout | Reference |
|---|---|
| Quick connectors | CLE24 / CLE34 / CLE54 / CLE4-5 |
| In-line terminal blocks | REV-2,5 / REV-4 / REV-6 / REV-10 |
| Cable terminals (ES) | TE / TE2 / TF / TH / TL / TPCU / TPP / TR / TTR |
| Strip terminal blocks | RE / 108P / 112P |
| DIN rail terminals | TCD |
| Cap connectors | CLC5 / CLC16 / CLC32 / CLG15AZ |
| IP68 connectors | CE-3P / CE-3PV / CE-3P4T |
| Splices and heat-shrink tubing | CTR / TBR / BOLTBR |
| Distribution blocks | 105 / 113 / 180 / 128 / 212 |
Selection and installation
Decide whether the task is joining cables, preparing their ends, distributing circuits or covering an existing joint. Check conductor type and section, voltage, current, geometry and connection method for the reference. IP classification belongs to the declared product and mounting arrangement; not every connector is watertight. Heat-shrink tubing does not replace the component making electrical contact.
Respect electrical limits and the instructions for the reference and receiving equipment. Disconnect the supply before making connections; nominal section alone does not validate the assembly.
Frequently asked questions
Do a terminal and a connector perform the same function?
A terminal prepares a conductor end for a specific interface; a connector or terminal block joins or distributes conductors as designed. Select both for the intended connection.
Is every product in this family IP68?
No. IP68 identifies a dedicated category. CLG15AZ specifies IP67; other ranges must be assessed using their own data and mounting conditions.
Can I select by colour alone?
No. Colours vary by family and reference. Check the code, section, conductor type and geometry; matching colours do not guarantee compatibility.