Air Condition Boxes
Flush-mounted solutions to simplify and secure the pre-installation of air conditioning systems in new builds or renovations.
- Durable thermoplastic material: High resistance and adaptability on site.
- Water outlet: vertical for 77 and 177; horizontal for 78 and 178.
- Internal connection box 665: included with references 77 and 78.
- Flush-mounted design: Clean and professional wall integration.
Flush box for air conditioning pre-installation. With independent and reversible evacuator with vertical water outlet. Also with sealed box ref. 665 to make connections.
Flush box for air conditioning pre-installation. With independent and reversible evacuator with vertical water outlet.
Air conditioning pre-installation boxes: vertical or horizontal water outlet
Solera air conditioning pre-installation boxes prepare a recessed space in the wall for organising incoming services and water drainage before the equipment is fitted. These thermoplastic boxes are intended for flush mounting in masonry in indoor domestic and tertiary settings. References 77, 177, 78 and 178 offer a choice of drainage direction and an internal box for electrical connections.
Comparison of the four references
| Reference | Water outlet | Internal connection box 665 |
|---|---|---|
| 77 | Vertical | Included |
| 177 | Vertical | Without internal box |
| 78 | Horizontal | Included |
| 178 | Horizontal | Without internal box |
References 77 and 177 have a vertical water outlet; 78 and 178 have a horizontal outlet. The drainage unit is described as independent and reversible. This does not establish that every reference can be converted from vertical to horizontal: select according to the drainage type specified for each model. References 77 and 78 include internal watertight connection box 665; references 177 and 178 are supplied without that internal box.
Box features and wall recess preparation
The data sheets specify 30 knockout entries for Ø 32 mm conduit, a central anti-deformation partition and a plastic-claw cover with the option of using screws at the same time according to the product description. The claw fixes the cover; it does not describe a hollow-wall anchoring system for the box.
The reference characteristics tables state internal dimensions of 430 × 147.5 × 65 mm. Check the drawing and instructions for the selected reference before preparing the wall recess: internal dimensions must not automatically be used as the required wall opening. Coordinate box position, incoming services and the drainage route with equipment and project requirements.
How to select the installation version
First determine whether the drainage route requires a vertical or horizontal outlet. Then decide whether the version including connection box 665 is required. Check available space, conduit entries and planned access before closing the wall. The pre-installation box data sheets declare IP40 and IK07. The internal watertight box supplied with some versions is a separate component and does not make the entire assembly an outdoor weatherproof enclosure.
Consult available drawings, data sheets and instructions in Solera technical documentation. Where the project includes surface service routes, also see air-conditioning trunking accessories and select fixings and sizes to match the trunking used. They complement the route and are not automatically supplied with the pre-installation box.
Frequently asked questions about air conditioning pre-installation boxes
How do 77, 177, 78 and 178 differ?
References 77 and 177 have vertical outlets; 78 and 178 have horizontal outlets. References 77 and 78 also include internal watertight box 665 for electrical connections, while 177 and 178 do not. Selection combines drainage direction and the need for the internal box.
Which dimensions should be used for the wall opening?
The characteristics table lists internal dimensions of 430 × 147.5 × 65 mm. Use the drawing and instructions for the selected reference to establish the required recess. Consider wall construction, finishes and incoming services: internal dimensions are not necessarily the wall opening dimensions.
Are versions with a watertight internal box automatically suitable outdoors?
This application must not be inferred from the internal box. The pre-installation box data sheets specify an indoor location and IP40. The 665 box included with 77 and 78 is for connections inside the enclosure. Check the protection and intended use of the complete assembly by reference.