IP68 connection boxes (Black series)

Solera IP68 connection boxes house electrical connections under the operating conditions specified for each reference.

  • IP68 protection: check depth, duration and installation conditions.
  • References: BK-3P, BK-3PT and BK-6P.
  • Selection: verify terminals, conductor section, entries and usable dimensions.

IP68 connection boxes: selection and immersion conditions

Solera IP68 connection boxes house electrical connections through references including BK-3P, BK-3PT and BK-6P. Check terminal equipment, entries and declared protection conditions for each model. Read IP68 together with the specified depth, duration and installation requirements.

Checking each box’s product sheet

For example, BK-3P declares IP68 for 48 hours at a maximum depth of 4 metres. Its sheet lists three cable gland entries, an included terminal block and a conductor section of 4 mm². It also declares UV resistance and an ambient operating range of −5 to +60 °C. These are BK-3P specifications, not shared data to assume for BK-3PT or BK-6P.

Compare references using entry count and layout, permitted conductor section, terminal capacity and usable space. Check dimensions and drawings before reserving installation space: external size is different from connection space.

Entry installation and closure

Cable outside diameter and conductor section are different measurements. Confirm that each entry can seal around the cable used, and follow the installation and closure instructions. The specified protection requires these conditions; it does not imply unlimited immersion or suitability for every wet location.

If immersion is unnecessary, compare IP65 boxes without cones by entries and dimensions. Check compatibility before modifying an IP68 box with additional components.

To complete your selection, consult: IP65 boxes without cones · sealed box accessories · Sealed Boxes · technical documentation.

Frequently asked questions

Does IP68 mean the box can remain submerged indefinitely?

No. Apply the declared conditions for the reference. BK-3P specifies 48 hours at a maximum depth of 4 metres; do not extend that limit without confirming documentation.

Does every box in this category include the same terminal block?

Do not assume this. BK-3P lists an included terminal block; check terminals, capacity and supplied equipment individually for BK-3PT and BK-6P.

Is a 4 mm² conductor section enough to select a cable entry?

No. Conductor section differs from cable outside diameter. Cable gland sealing depends on outside diameter and the gland’s accepted range. Check both measurements in the documentation.