Manual

  • Wired reels, empty 70 drum and unwired TB7427/3.
  • Cable lengths from 3 to 50 m, depending on reference.
  • Cable cross-sections of 1, 1.5 or 2.5 mm², depending on model.
  • H05VV-F cables and selected French-socket versions with H07RN-F.
  • 7321USB: three mains sockets and two USB outlets.
  • Check power limits, IP rating, operating conditions and accessory compatibility.

Solera manual cable reels: compare cables, sockets and formats

Solera manual reels allow a supply cable to be extended and wound by hand. The category includes wired products, the empty 70 drum, the unwired TB7427/3 and accessories. Select by reference: cable type, socket count, covers and permitted load are not the same across the range.

Wired model comparison

ReferenceSockets / formatLengthCable
7321USB3 + 2 USB5 mH05VV-F 3G1,5 mm²
742943 mH05VV-F 3G1,5 mm²
7211/124,5 mH05VV-F 3G1,5 mm²
7412/1410 mH05VV-F 3G1 mm²
7422/3410 mH05VV-F 3G1,5 mm²
7413/2415 mH05VV-F 3G1,5 mm²
7423/2415 mH05VV-F 3G1,5 mm²
7425/2425 mH05VV-F 3G1,5 mm²
7427/2450 mH05VV-F 3G1,5 mm²
7425/1T4 · covered25 mH05VV-F 3G1,5 mm²
7427/1T4 · covered50 mH05VV-F 3G1,5 mm²
7437450 mH05VV-F 3G2,5 mm²
7425F/1TG4 · covered25 mH07RN-F 3G1,5 mm²
7435F/1TG4 · covered25 mH07RN-F 3G2,5 mm²
74340F/1TG4 · covered40 mH07RN-F 3G2,5 mm²
74240F440 mH05VV-F 3G1,5 mm²

Empty drum, unwired reel and accessories

Reference 70 is an empty domestic drum; it is different from TB7427/3, supplied without cable but with four 2P+E sockets. To assemble TB7427/3, follow its instructions for permitted cable, cross-section and drum capacity; assembly is for authorised personnel. SOP-7000 is a wall support and ROL-1 a manual cable winder. These accessories do not add electrical outlets or protective functions; check compatibility before selecting them.

ReferenceSockets / format
70Empty drum
TB7427/3Without cable, 4 sockets 2P+E
SOP-7000Wall support
ROL-1Manual cable winder

Combined load and operating conditions

Solera’s general instructions require the cable to be fully unwound before connection to the supply. The load permitted with the cable wound is lower than with it fully unwound. Additional sockets do not multiply this limit. Compare cable type, cross-section, IP rating and the application declared for each model; a socket cover alone does not establish suitability for outdoor use. 7321USB adds two USB outlets to three mains sockets: do not assume fast charging or a separate power allowance per port without supporting documentation.

Manual cable reel questions

Can any cable be fitted to TB7427/3?

No. Follow the permitted types, cross-sections and drum capacity stated in its instructions. Length must be checked together with cross-section.

What is the maximum power of a manual reel?

It depends on the reference and whether the cable is wound or unwound. Check the product marking and documentation and observe the limits of the complete assembly and installation.

Are covered sockets suitable for every outdoor application?

No. Check the product’s IP rating, cable type and declared conditions of use. Covers do not replace this assessment.

General safety and operating instructions

TB7427/3 · Assembly instructions